Skip to main content

FREE SHIPPING from € 99,- / DE / AT

FREE SHIPPING: DE, AT... from 100,- € / CH ... from 199,- / FR, BE, BG, FR, IT, HR, NL ... from 299,- €

FREE SHIPPING from € 99,- / DE / AT

Voltage [V]: 0-60V
Abmessungen: 27/19/11 mm
Max A: 75 A
Weight: 15 g

Voltage and current sensor (up to 75A) in combination with the Jeti Duplex system.

The MUI sensors are designed to measure voltages, currents and used battery capacity in the model. The JETIBOX terminal is used to display the measured values and the 2.4GHz DUPLEX system for wireless transmission of information. The DUPLEX system uses the 2.4GHz band for communication, which not only allows the transmission of remote control data to the model, but also the transmission from the model back to the transmitter. The telemetric data acquired during operation are transmitted in real time and the current status of the measured quantities can be displayed on the LCD screen of the JETIBOX. The MUI telemetric sensors allow you to measure voltages and currents in your model and transmit this information using the DUPLEX system (receiver and transmitter module). Thanks to the high current measurement accuracy, these sensors allow the consumed capacity of the measured battery to be tracked. In addition to the duration of the current passage, the MUI unit also records the average value and maximum values of the current. Furthermore, it offers the exact voltage values as well as their minimum and maximum values.
The JETIBOX terminal is used to set parameters and display the measured values.
The MUI sensors enable the setting of an acoustic signal when set parameters are exceeded. This alarm message can be set for measuring the maximum current, minimum voltage and maximum permissible capacity consumption. The acoustic signal is generated by the transmitter module via a built-in sound generator. Individual alarm messages are distinguished from each other by the assignment of a Morse alphabet letter. The acoustic signals for parameter overruns are generated even if no JETIBOX is connected. When the JETIBOX is connected, the LCD display shows which parameter has been exceeded. If several parameters are exceeded, the acoustic signals and LCD displays alternate.

JETI
JETI DUPLEX 2.4EX TELEMETRY SENSOR MUI 75A
Product number: 94038
Manufacturer number: 80001303

€47.90*

In stock. Usually ships within 1 business day.

Voltage [V]: 0-60V
Abmessungen: 27/19/11 mm
Max A: 75 A
Weight: 15 g

Voltage and current sensor (up to 75A) in combination with the Jeti Duplex system.

The MUI sensors are designed to measure voltages, currents and used battery capacity in the model. The JETIBOX terminal is used to display the measured values and the 2.4GHz DUPLEX system for wireless transmission of information. The DUPLEX system uses the 2.4GHz band for communication, which not only allows the transmission of remote control data to the model, but also the transmission from the model back to the transmitter. The telemetric data acquired during operation are transmitted in real time and the current status of the measured quantities can be displayed on the LCD screen of the JETIBOX. The MUI telemetric sensors allow you to measure voltages and currents in your model and transmit this information using the DUPLEX system (receiver and transmitter module). Thanks to the high current measurement accuracy, these sensors allow the consumed capacity of the measured battery to be tracked. In addition to the duration of the current passage, the MUI unit also records the average value and maximum values of the current. Furthermore, it offers the exact voltage values as well as their minimum and maximum values.
The JETIBOX terminal is used to set parameters and display the measured values.
The MUI sensors enable the setting of an acoustic signal when set parameters are exceeded. This alarm message can be set for measuring the maximum current, minimum voltage and maximum permissible capacity consumption. The acoustic signal is generated by the transmitter module via a built-in sound generator. Individual alarm messages are distinguished from each other by the assignment of a Morse alphabet letter. The acoustic signals for parameter overruns are generated even if no JETIBOX is connected. When the JETIBOX is connected, the LCD display shows which parameter has been exceeded. If several parameters are exceeded, the acoustic signals and LCD displays alternate.